Roll over image to zoom in
Save 20%
ThermElc GlobalSKU: ALD-100
Description
- 【Higher Sensitivity, Longer Probe】14 inches flexible probe shaft with 3 alternative sensor tips. 7 adjustable sensitivities with the max sensitivity of 0.11oz/yr.
- 【18 levels of Alarm Indications】The Electronic Refrigerant Leak Detector features 18 alarm levels from low to high to help you home in on a leak. The alarm level will increase as the leak is approached.
- 【Fast Response】Once the power button is pressed, the detector will be ready to use. Response in 3 seconds; Warm up in 6 seconds. Reset in 2 seconds. Powered by: 2 C Alkaline batteries(included)
- 【Reset Function】Features a reset function that will set the tester to ignore the ambient or baseline level of halogenated refrigerants in the atmosphere. This allows you to identify leaks without the false positives of the background concentration.
- 【Detecting All Halogenated Gases】It can detect all kinds of halogen refrigerants including CFCs, HFCs, HCFCs, HCs, HFOs, and Blends. Detect SF-6 in high-voltage circuit breakers. Detect most gases that contain Chlorine, Fluorine or Bromine (the halogen gases). Detect cleaning agents used in dry cleanings, such as perchloroethylene.
Featuring 7 sensitivity and 18 alarm levels, Aprvtio ALD-100 electronic refrigerant leak detector recognizes most gases that contain chlorine, fluorine or bromine - also known as halogen gases. The internal microprocessor identifies extremely small concentrations of halogen gases in refrigeration systems, dry cleaning systems, and high-voltage circuit breakers. The detector comes with a 14 in. flexible probe, two sensing tips, aluminum case and two C-batteries.
The length of the manual is limited, and the refrigerant gas model that can be detected is not written, please use this page as the standard.
Features
Battery Level Indicator
If the batteries are dead or not installed, the LED will not light at all. If the batteries are not fully charged or properly installed, performance may be affected and readings might not be accurate. | Reset Function/ Automatic CircuitIf a full alarm is indicated before you have found the source of the leak, you can reset the detector to zero by pressing the reset key. This will allow you to find progressively greater concentrations, and eventually find the source of the leak. | 3 Replacement SensorsThis tester will detect most gases which contain Chlorine, Fluorine or Bromine (the halogen gases). Microprocessor driven, this leak detector will identify halogenated refrigerants in concentrations as small as 3 Gr. per Yr. The microprocessor samples the halogen concentration and battery voltage level continuously, resulting in a very stable and reliable real time readout. | 2C BatteriesPower supply: 2C Alkaline batteries (included in the package) 1. To install batteries, remove the battery compartment door which is at the bottom of the case by sliding it up. 2. Install two “C” batteries with both positive polarity toward the battery compartment door. |
Quick Start Guide
1. Turn on the device by pressing the ON button. The display will show the indication for 3 seconds. The first light flashes green to prove that the battery is good. | 2. A continuous beep tone will indicate the unit is normally functioning. Press the arrow up or down button to change the sensitivity. The default level of sensitivity is 5. | 3. When a leak is located, the beep tone will change to a siren tone. Also, you will see the LED display the alarm. | 4. Reset key will allow you to find progressively greater concentrations, and eventually find the source of the leak. |
Specifications
Probe length | 14 in. |
Product Length | 9.25 in. |
Product Height | 2-1/2 in. |
Application | R12, R11, R500, R22, R123, R124, R502, R134a, R404a, R125 refrigerants and blends such as HP62 and MP39 |
Customer Reviews
Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Estimate shipping
Refund Policy
We have a 30-day return policy, which means you have 30 days after receiving your item to request a return.
To be eligible for a return, your item must be in the same condition that you received it, unworn or unused, with tags, and in its original packaging. You’ll also need the receipt or proof of purchase.
To start a return, you can contact us at sales@thermelc.com. If your return is accepted, we’ll send you a return shipping label, as well as instructions on how and where to send your package. Items sent back to us without first requesting a return will not be accepted.
You can always contact us for any return question at sales@thermelc.com.
Damages and issues
Please inspect your order upon reception and contact us immediately if the item is defective, damaged or if you receive the wrong item, so that we can evaluate the issue and make it right.
Exceptions / non-returnable items
Certain types of items cannot be returned, like perishable goods (such as food, flowers, or plants), custom products (such as special orders or personalized items), and personal care goods (such as beauty products). We also do not accept returns for hazardous materials, flammable liquids, or gases. Please get in touch if you have questions or concerns about your specific item.
Unfortunately, we cannot accept returns on sale items or gift cards.
Exchanges
The fastest way to ensure you get what you want is to return the item you have, and once the return is accepted, make a separate purchase for the new item.
Refunds
We will notify you once we’ve received and inspected your return, and let you know if the refund was approved or not. If approved, you’ll be automatically refunded on your original payment method. Please remember it can take some time for your bank or credit card company to process and post the refund too.